I bought some test leads with banana plugs and alligator clips for £0.99 on Ebay from Hong Kong. They were described as "Alligator Probe Test Leads Clip Pin to Banana Plug Cable for Digital Multimeter GF". I don't know what the GF means.
Very cheap and what could possibly be wrong with them? Well actually, almost everything!
The first time I used them to connect a regulator to a bench PSU they got hot and dropped several volts. Without needing to do any sums with wire gauge and current I felt the resistance must be too high, so I measured it to be about 1.4Ω for the round trip. Way too high as multimeter leads are generally about 0.2Ω.
I unscrewed a plug and found this: -
The screw bites down on the soft insulation and that presses the folded back strands against the barrel. Not the best way to make a connection as you want the screw biting down directly on the strands, or better still a ferrule.
At the clip end it was more of the same: -
The strands are trapped between metal and plastic again instead of being soldered through the hole. The crimp is there just for mechanical strain relief, not the electrical connection.
I removed all the connectors (the clips pull off really easily due to not being soldered) and measured the resistance of the wire on its own. Still 1.4Ω, too much I felt for that gauge of copper wire 2m long. The simple explanation is that it isn't copper.
The fact it sticks really well to magnets leads me to believe it is copper plated steel. That might be OK for measuring voltage but no good for measuring or carrying current. I can't see any reason for using it other than it must be cheaper.
I replaced it with 32/0.2mm copper wire half the length and got a total resistance of 20mΩ. Much more suitable for hooking up PSU test circuits but a bit less flexible than ideal for multimeter leads.
So basically I got usable connectors for £0.99, which is still probably cheaper than I could buy them for in the UK. The wire and the construction were junk.
Showing posts with label junkbusting. Show all posts
Showing posts with label junkbusting. Show all posts
Sunday, 3 April 2016
Tuesday, 29 March 2016
Beware of cheap Kelvin clip LCR meter test leads
When I first got my Elektor LCR meter I didn't have any four wire test leads for it so I made up a pair from the ends of an old VGA monitor cable and some miniature crocodile clips.
These worked well enough for measuring normal components but they are not true Kelvin leads because the wires meet at the crocodile clips, not at the device under test. The steel clips add about 3mΩ and 200nH. True Kelvin clips insulate the two jaws from each other and one wire goes to each jaw. They also have non-ferrous jaws, so are less inductive and more conductive.
I found some suitable clips at RS for £9 and was going to buy a pair of those and make up my own leads until I found I could buy them ready made on eBay for only £6.70 from Hong Kong, bargain! So I purchased a set : -
N.B. they had red and black sleeving when I bought them. This picture is after I fixed them!
When I tried them out I found that the readings were very inconsistent and the open circuit capacitance increased when the wires were moved close to each other. That made me think the wires were not screened cable so I opened one of the BNC connectors to check.
What I found was the cable is actually screened, in fact it has both a copper braid screen and an inner aluminium foil screen like digital TV coax. However the screen is not connected to to the BNC outer contact, it is cropped back to the insulation. It was the same in all four BNC plugs so I had to remake all those connections.
Then I found that the screens were shorted to the inner core at the clip end! I had to cut off the red and black sleeving and completely disassemble the clips.
It is as if the person making them didn't understand the concept of screened cable and just used it like normal single conductor wire. Much easier and faster to assemble that way of course.
So I had to remake all four of those connections as well, stripping back the screen and covering it with heat shrink sleeving.
Another problem is the insulation tape that prevents the jaws being shorted together by the spring that holds them closed is not tough enough and was already starting to fail.
To fix this I added some heat shrink sleeving to the spring.
I then hot glued the wires in place as there isn't much strain relief and replaced the outer sleeving with 19mm heat shrink. That is why mine ended up grey instead of red and black.
They now work well but remaking all eight ends was a lot of time and materials. The seller was apologetic and gave me a refund but I wonder how many other ones like this are out there. I also ordered Kelvin tweezers for surface mount devices and a 4 terminal test fixture from China, so it will be interesting to see if they are built properly.
These worked well enough for measuring normal components but they are not true Kelvin leads because the wires meet at the crocodile clips, not at the device under test. The steel clips add about 3mΩ and 200nH. True Kelvin clips insulate the two jaws from each other and one wire goes to each jaw. They also have non-ferrous jaws, so are less inductive and more conductive.
I found some suitable clips at RS for £9 and was going to buy a pair of those and make up my own leads until I found I could buy them ready made on eBay for only £6.70 from Hong Kong, bargain! So I purchased a set : -
N.B. they had red and black sleeving when I bought them. This picture is after I fixed them!
When I tried them out I found that the readings were very inconsistent and the open circuit capacitance increased when the wires were moved close to each other. That made me think the wires were not screened cable so I opened one of the BNC connectors to check.
What I found was the cable is actually screened, in fact it has both a copper braid screen and an inner aluminium foil screen like digital TV coax. However the screen is not connected to to the BNC outer contact, it is cropped back to the insulation. It was the same in all four BNC plugs so I had to remake all those connections.
Then I found that the screens were shorted to the inner core at the clip end! I had to cut off the red and black sleeving and completely disassemble the clips.
It is as if the person making them didn't understand the concept of screened cable and just used it like normal single conductor wire. Much easier and faster to assemble that way of course.
So I had to remake all four of those connections as well, stripping back the screen and covering it with heat shrink sleeving.
Another problem is the insulation tape that prevents the jaws being shorted together by the spring that holds them closed is not tough enough and was already starting to fail.
To fix this I added some heat shrink sleeving to the spring.
I then hot glued the wires in place as there isn't much strain relief and replaced the outer sleeving with 19mm heat shrink. That is why mine ended up grey instead of red and black.
They now work well but remaking all eight ends was a lot of time and materials. The seller was apologetic and gave me a refund but I wonder how many other ones like this are out there. I also ordered Kelvin tweezers for surface mount devices and a 4 terminal test fixture from China, so it will be interesting to see if they are built properly.